Fridge Repair in Johannesburg

Same-day service On-site repair Call 072 686 0472

Fridge warm, freezer iced up, or water on the kitchen floor? A technician comes to your home in Sandton, Randburg, Fourways, Midrand or the East Rand, finds the fault and gives you a fixed quote before any work starts.

Updated

🔍 R350 call-out to inspect & diagnose · waived if we do the job⚡ Same-day call-outs · 90% of major spares carried
✓ Genuine OEM parts wherever available✓ 10+ years' experience · 10,000+ jobs✓ 6-month guarantee✓ R350 call-out, waived if we do the job✓ Same-day call-outs✓ Fixed quote before any work✓ 90% of major spares carried✓ All of Gauteng

Quick answer

Absolute Repairs provides fridge and freezer repair in Johannesburg, on site at your home or business, covering Johannesburg, Sandton, Randburg, Fourways, Midrand and Bedfordview. The R350 call-out covers the visit and a proper diagnosis, and you get a fixed price before any work is done. We are available Monday to Saturday, 07:30–17:30, and a WhatsApp to 072 686 0472 is the quickest way to book.

Why Johannesburg fridges fail

Most fridge breakdowns we see in Johannesburg trace back to one of three things: power, heat and age. Highveld summer storms bring lightning and power dips, and the surge when electricity returns after an outage is hard on control boards and inverter compressors. A fridge squeezed into a tight kitchen alcove or a hot garage also runs longer than it should, which wears out fans and start devices.

The good news is that most of these faults are repairable on site. Replacing a fridge is rarely the only option, especially for a modern side-by-side or a built-in unit that cost a lot to begin with.

Fridge faults we repair on site

Fridge warm, freezer fine

Usually a blocked defrost drain, a failed defrost heater or a stopped evaporator fan. See our guide on why the fridge is warm while the freezer is cold.

Not cooling at all

Start relay, compressor, thermostat or a gas leak. We test each part before quoting, so you're not paying for guesswork.

Ice build-up

Heavy frost on the back wall or freezer drawers points to a defrost system fault or a worn door seal.

Water leaking

Blocked drain tubes, a cracked drip tray, or a leaking water dispenser line on plumbed-in fridges.

Dead after a power cut

Control board (PCB) and inverter faults after a surge. We can also write the report for your insurance claim.

Noisy or clicking

Fan motors, a compressor struggling to start, or a loose condenser fan underneath.

Brands we fix in Johannesburg

We repair Samsung, LG, Defy, Bosch, Whirlpool, Smeg, Hisense and KIC fridges, including side-by-side, French-door and built-in models. Brand pages: Samsung Johannesburg, LG Johannesburg, Defy Johannesburg, Bosch Johannesburg.

Johannesburg areas we cover

What happens when you book

  1. Call or WhatsApp us with the brand, model and what the fridge is doing. A photo of the rating plate inside the door helps.
  2. We confirm a time slot, usually the same day.
  3. The technician tests the fridge in your kitchen. The R350 call-out covers this diagnosis.
  4. You get a fixed price for the repair. Most common parts are on the van, so many fridges are running again on the first visit.

Tip while you wait: move perishables to a cooler box and keep the doors closed. If the fridge is iced up, switching it off with the doors open for a few hours can get it cooling briefly until we arrive.

A recent fridge job in Johannesburg

KIC fridge-freezer compressor destroyed by a power surge

Kyalami, Midrand · KIC fridge-freezer · Fixed: compressor replaced

The KIC fridge-freezer stopped cooling after a power surge. Our tests showed the surge had damaged the compressor, the pump that circulates the gas. We replaced the compressor and the fridge and freezer are back to temperature. Surge damage like this is often covered by home insurance, and we can provide the technical report your insurer asks for.

KIC fridge-freezer after its compressor was replaced in KyalamiInside the repaired KIC fridge-freezer, cooling again after a compressor replacement

Recent jobs

Shop display fridge not cooling: regassed

Parkhurst · Commercial open-front multideck drinks display fridge · Fixed: regassed, cooling again

This open-front drinks display fridge in a Parkhurst shop had stopped cooling, which meant cold drinks, milk and juice were warming up on the shelves. We checked the system on site and it was short of refrigerant gas. We regassed it, and the fridge was cooling properly again. Tip: open-front display fridges work hard all day, because there is no door to keep the cold in. If the drinks on the shelves don't feel properly cold, or the display temperature keeps climbing during the day, call us early: in a shop, a fridge that slowly loses cooling costs you stock before it stops completely.

Open-front drinks display fridge in a Parkhurst shop after being regassedCommercial multideck display fridge that was not cooling in Parkhurst

Smeg French-door fridge not cooling: blocked drain, ice jamming the fan

Alberton · Smeg French-door fridge-freezer · Fixed: ice cleared, blocked defrost drain unblocked, fan running freely

This Smeg French-door fridge in Alberton had stopped cooling. The cause started with a blocked defrost drain. Every time the fridge defrosts, the melted water is meant to run away through the drain. With the drain blocked, the water stayed behind and froze, and the ice kept building up until it caught the fan blade. With the fan jammed, no cold air was being pushed through the fridge, so it stopped cooling even though the cooling system itself was working. We cleared the ice, unblocked the drain so the defrost water can run away again, and got the fan turning freely. The display was back to −20 °C in the freezer and 4 °C in the fridge. Tip: if your fridge stops cooling and you hear a scraping or ticking noise from the back of the freezer, or see ice building up on the back wall, it is often ice hitting the fan. Switch the fridge off and call us, rather than chipping at the ice, which can damage the evaporator.

Smeg French-door fridge display showing minus 20 freezer and 4 degrees fridge after the repair in Alberton

Defy side-by-side not cooling: compressor not running, relay and overload replaced

Sandton · Defy side-by-side fridge-freezer with water dispenser · Fixed: start relay and overload replaced, new filter drier, service

The customer in Sandton called because the freezer side of their Defy side-by-side had stopped getting cold, but they thought the fridge side was still fine. When we checked, neither side was actually cold: the fan was still blowing air into the fridge, which felt cool on the hand, but the compressor wasn't running at all. We traced that to a faulty start relay and overload, the small parts on the side of the compressor that help it start and protect it from overheating. We replaced them, fitted a new filter drier, and gave the fridge a service while the system was open. The display was back to −18 °C in the freezer and 4 °C in the fridge. Tip: air blowing out of the vents doesn't mean a fridge is cooling. If food is going soft, check whether the compressor at the bottom back is running. If it is silent, or clicks every few minutes without starting, the start relay is a common cause.

Defy side-by-side fridge with water dispenser that was not cooling in SandtonDefy side-by-side with the freezer panel off showing the evaporator coil and fan in SandtonGauges and torch at the back of a Defy fridge while fitting a new filter drier in SandtonDefy fridge display showing minus 18 freezer and 4 degrees fridge after the repair in Sandton

Siemens side-by-side fridge warm and dispenser leaking: evaporator fan motor and cracked water pipe replaced

Kempton Park · Siemens side-by-side fridge-freezer with water dispenser · Fixed: evaporator fan motor replaced, cracked water pipe replaced

This Siemens side-by-side fridge in Kempton Park had two problems at once: the fridge section wasn't getting cold, and the water dispenser leaked every time someone pressed it for water. On a side-by-side like this, the cooling coil (the evaporator) sits behind a cover in the freezer, and a fan blows the cold air from there through to the fridge side. When that fan motor fails, the freezer can still feel cold while the fridge slowly warms up. We took off the cover, which you can see in the first photo, and replaced the faulty evaporator fan motor. The leak was a separate fault: the water pipe that feeds the dispenser had cracked, so water escaped whenever it was under pressure. We replaced the pipe and checked the dispenser for leaks. Both sides were cooling again and the dispenser was dry. Tip: if your fridge is warm but the freezer is fine, listen for the fan at the back of the freezer when the door is closed. If it's silent or noisy, the fan motor is a likely cause, and it's a much smaller repair than a gas fault.

Siemens side-by-side fridge with the freezer evaporator cover removed to replace the fan motor in Kempton ParkSiemens side-by-side fridge water dispenser working again after the cracked pipe was replaced in Kempton Park

Defy fridge warm while the freezer stayed cold: sealed gas system repaired

Greenstone Hill · Defy fridge-freezer · Fixed: sealed system repaired at the compressor pipework and recharged with gas

The customer's Defy fridge-freezer in Greenstone Hill had a cold freezer, but the fridge section was very warm. On this type of fridge, the gas runs through the freezer first and then on to the fridge side, so when the system is low on gas or partly blocked, the freezer can still get cold while the fridge never does. That's why a working freezer doesn't mean the gas side is fine. Our technician repaired the sealed system on site, brazing the pipework at the compressor, which you can see in the photos, and then recharged it with gas and ran it until both sections were cooling properly. Tip: if your freezer is cold but the fridge is warm, check first that the fridge vents aren't blocked by food and that the thermostat hasn't been turned down. If both are fine, it's usually a gas or defrost problem, and it's worth getting it checked before the compressor is put under strain.

Technician repairing the sealed gas system on a Defy fridge in Greenstone HillBrazing the compressor pipework on a Defy fridge that was warm in the fridge section, Greenstone Hill

Under-counter bar fridge not cooling: system flushed, new filter drier and regas

Lonehill · Double-door under-counter bar fridge · Fixed: system flushed, filter drier replaced, regassed

This glass-door bar fridge in a Lonehill home entertainment area had stopped getting cold. With our gauges connected, the readings pointed to a problem inside the sealed system rather than a simple fault like a fan or thermostat. We flushed the system to clear out contamination and moisture, fitted a new filter drier, then vacuumed and regassed it to the correct charge. Afterwards we put a thermometer probe inside and watched the temperature come down to show the customer it was cooling properly again. Tip: bar fridges built in under a counter need space to breathe. Keep the vents at the front or bottom clear, because a bar fridge that can't get rid of its heat works much harder and wears out sooner.

Gauges connected to flush and regas an under-counter bar fridge in LonehillBar fridge compressor and new filter drier fitted during the repair in LonehillGlass-door under-counter bar fridge with a thermometer probe showing it cooling again in Lonehill

Defy fridge in a camper: gas leak repaired before the festive season

Rivonia · Defy fridge-freezer in a camper · Fixed: gas leak repaired, system regassed

This customer's camper has a Defy fridge-freezer built in beside the seating area, and it had stopped cooling just as the camping season was coming up. We worked on it right there in the camper. Our pressure test showed the system had lost its gas through a leak. Campers and caravans take a lot of vibration on the road, which is hard on a fridge's pipework and joints over time. We found and repaired the leak, then connected our gauges and regassed the system to the correct charge, and checked the fridge and freezer were cooling down properly. The customer is ready to head off camping for the festive season with cold drinks and fresh food. Tip: run your camper or caravan fridge at home for a day or two before a trip. If it isn't getting properly cold, you'll have time to get it fixed before you leave.

Defy fridge in a camper connected to gauges for a gas leak repair and regas in Rivonia

Caravan fridge: freezer cold, fridge warm, gas leak repaired

Springs · Caravan fridge-freezer · Fixed: gas leak repaired, system regassed with R134a

This caravan fridge had a strange fault. The freezer was still cold, but the fridge section wasn't getting cold at all. Most people would guess a thermostat or a fan, but our diagnosis showed the real cause was a gas leak. When a fridge slowly loses gas, the little refrigerant left boils off in the first part of the cooling circuit, which is usually the freezer, and runs out before it reaches the fridge section. So the freezer keeps working for a while and the fridge goes warm. We found and repaired the leak, then regassed the system with R134a, connected to our gauges to get the charge right. Both the freezer and the fridge section were cooling properly again. Tip: if your freezer is cold but the fridge is warm, don't wait. A slow leak only gets worse, and once the freezer starts warming up too, the compressor has been working overtime for weeks.

Caravan fridge connected to gauges and an R134a cylinder for a gas leak repair and regas in SpringsCaravan fridge-freezer cooling again after the gas leak repair in Springs

Fridge not cooling from a blockage: new filter drier and regas

Bryanston · Fridge-freezer · Fixed: blocked system cleared, new filter drier, vacuumed and regassed

This fridge was running but not cooling properly. Gauge readings showed a restriction in the sealed system rather than a leak. The filter drier, a small copper canister that traps moisture and dirt in the gas, was blocked, so the refrigerant couldn't flow. We fitted a new filter drier, vacuumed the system to remove moisture, and regassed it to the correct charge, then checked the fridge was cooling down properly again. Tip: a fridge where the compressor runs non-stop but the cabinet stays warm can have a blockage, not just low gas. Topping up gas won't fix that, which is why we test first.

New filter drier ready to fit to a blocked fridge in BryanstonGauges and refrigerant cylinder connected to regas a fridge in Bryanston

Defy side-by-side fridge: main control board replaced

Johannesburg South · Defy side-by-side fridge-freezer · Fixed: main control board replaced

This white Defy side-by-side had stopped working properly. Our diagnosis traced the fault to the main control board, the electronic board that switches the compressor, fans and defrost. Many Defy side-by-sides use Samsung-made electronics, and this one had a Samsung control board. We replaced the board, reconnected the wiring and tested the fridge and freezer running normally again. Tip: a fridge that clicks, runs erratically or goes completely dead while the light still works can point to a board fault, but the compressor, fans and sensors need testing first so you don't pay for a board you don't need.

White Defy side-by-side fridge-freezer repaired in Johannesburg SouthControl board on a Defy side-by-side fridge being replaced in Johannesburg South

12V DC caravan fridge not cooling: gas leak repaired, new drier and regas

Bedfordview · 12V DC compressor caravan fridge · Fixed: leak repaired, filter drier replaced, system regassed

This 12V DC caravan fridge ran but wouldn't get cold. We tested it on a 12V supply to rule out the battery and wiring, then pressure-tested the sealed system and found a gas leak. We repaired the leak, fitted a new filter drier, vacuumed the system and regassed it, then checked it was cooling properly on 12V again. Caravan and camping fridges use the same kind of sealed gas system as a household fridge, just smaller, so they can be repaired the same way. Tip: caravan fridges take a lot of vibration on the road, which can crack pipe joints over time. If yours cools slower than it used to, get it checked before your next trip.

12V DC caravan fridge being repaired and regassed in Bedfordview

Glass-door drinks cooler leaking gas: leak repaired and regassed

Steyn City · Single-door glass display cooler in an outdoor entertainment area · Fixed: gas leak repaired, system regassed

This upright glass-door drinks cooler stands in a covered patio entertainment area, and it was leaking gas. Simply topping up the gas would only have lasted until it leaked out again, so our technician found the leak, repaired it with a brazing torch, then regassed the cooler to the correct charge and checked it was cooling again. Tip: coolers in outdoor areas work much harder in summer. Keep the grille at the bottom clear of dust and leaves, and leave space around the cooler so air can flow.

Single-door glass display drinks cooler in a patio entertainment area in Steyn City, repaired after a gas leakTechnician repairing a gas leak and regassing a glass-door drinks cooler in Steyn City

KIC caravan fridge: gas leak found, repaired and regassed

Bedfordview · KIC two-door fridge-freezer in a caravan · Fixed: gas leak brazed and system regassed

This KIC fridge-freezer is built into a caravan. We found a leak in the sealed gas system, repaired it by brazing the pipework, and then regassed the system to the correct charge. Fixing the leak first matters: regassing without repairing the leak just means the gas escapes again. Caravan fridges also get shaken on the road, which can stress pipe joints over time, so a cooling problem after a trip is worth having checked early.

Back of a KIC caravan fridge opened up for a gas leak repair by brazing in BedfordviewKIC two-door fridge-freezer built into a caravan, repaired and regassed in Bedfordview

LG side-by-side fridge regassed

Birch Acres, Kempton Park · LG side-by-side fridge-freezer (Inverter Linear compressor) · Fixed: system regassed

This LG side-by-side with an Inverter Linear compressor needed a regas. We checked the sealed system, regassed it to the correct charge, and made sure both the fridge and freezer sides came back down to temperature before we left. LG inverter fridges are well worth keeping going, and the compressor on this model carries a long manufacturer warranty.

LG side-by-side fridge-freezer with Inverter Linear compressor regassed in Birch Acres, Kempton Park

The same repair, done by our team elsewhere in Gauteng

Frequently asked questions

Can you repair a 12V caravan or camping fridge?

Yes. 12V DC compressor fridges used in caravans and 4x4s have a sealed gas system like a household fridge, so gas leaks, blockages and electrical faults can be repaired. On a recent Bedfordview job we repaired a gas leak on a 12V caravan fridge, fitted a new filter drier and regassed it.

Is it worth repairing my fridge or should I replace it?

If the fridge is under about 10 years old and the fault isn't a failed sealed system, repair is usually far cheaper than replacing it. We'll tell you honestly after the diagnosis if a repair isn't worth it.

Can you regas a fridge at my home?

Yes. If a leak is found, we locate and repair it before regassing. Topping up gas without fixing the leak just means the fridge fails again.

My fridge stopped working after load-shedding or a storm. Can you help with insurance?

Yes. We test the damaged parts and issue a technical report that insurers accept for surge and lightning claims.

Do you repair fridges in complexes and estates?

Yes. Give us the complex name and unit number when you book, and let security know to expect our technician.

Book a fridge repair in Johannesburg

Tell us your suburb, the fridge brand and what it's doing. Most bookings are seen the same day, Monday to Saturday, 07:30–17:30.

Related pages

Book a technician

Book a service call

Tell us what's broken and where you are. We'll call you back to confirm a time, usually the same day.

  • Genuine OEM parts fitted wherever they're available, and we tell you upfront if we use a quality equivalent
  • Technicians with over 10 years of experience and 10,000+ completed jobs
  • 6-month guarantee on every repair and installation
  • Flat R350 diagnostic call-out anywhere in Gauteng, waived if you go ahead with the repair
  • Fixed price agreed before any repair work starts
  • Same-day call-outs, and we carry around 90% of major spares
  • Prefer to talk? Call 072 686 0472 or WhatsApp us
Book a service call

R350 call-out to diagnose, waived if you go ahead with the repair. You get a fixed price before any work starts. We only use your details to arrange this repair.

📞 Call Now💬 WhatsApp📅 Book